Inspection Library

Waterproofing wet areas

Vertical membrane upturn and termination deficiencies

7 examples in 6 videos 7 major

What it is

The waterproofing membrane fails to terminate at the required height, leaving wall plasterboard paper exposed. Water entering behind the membrane risks tracking downstairs and causing substrate damage.

The vertical waterproofing upturn at the enclosed shower threshold measures only 5 mm rather than the required 15 mm above finished tile level. The non-compliant installation risks water bypassing the threshold and necessitates complete shower demolition.

The shower threshold in the main bathroom only achieves approximately 5 mm of vertical membrane upstand above the finished tile line, well under the prescribed 15 mm requirement. This failure enables sub-tile moisture penetration into surrounding rooms.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Finishes painting tiling

Video examples