Cladding render brickwork

Bushfire attack level (BAL) compliance failures and perimeter gaps

4 examples in 3 videos 3 major 1 minor

What it is

Gaps measuring up to 10 mm around external wall junctions breach bushfire ember protection thresholds and allow view directly to untreated internal framing timbers, providing an active route for water ingress.

Unsealed penetrations and clearances around external walls measure between 5 mm and 8 mm, breaching the maximum allowed gap size for ember protection.

Expanded polystyrene was installed on upper external walls without appearing on approved permit drawings or providing a Certificate of Conformity for the BAL 12.5 bushfire rating.