- Missing or Defective Shower Waterstop Angles
Waterproofing wet areas · 13 videos
18 - Excessive brickwork overhang at slab edge
Cladding render brickwork · 10 videos
13 - Missing or defective shower waterstop and enclosure barrier
Waterproofing wet areas · 8 videos
12 - Door jamb embedded with missing or flawed waterstop
Waterproofing wet areas · 9 videos
10 - Doorway and room perimeter waterstop non-compliance or omission
Waterproofing wet areas · 5 videos
10 - Cladding fastener and fixing defects
Cladding render brickwork · 8 videos
9 - Defective, unsealed, or bridged articulation and expansion joints
Cladding render brickwork · 4 videos
9 - Embedded door jambs and frames at wet areas
Waterproofing wet areas · 9 videos
9 - Bathroom & Wet Area Doorway Threshold Waterstops
Waterproofing wet areas · 7 videos
8 - Missing or non-compliant shower screen waterstop angles / vertical barriers
Waterproofing wet areas · 5 videos
8 - Movement and control joint defects in Hebel and cladding
Cladding render brickwork · 5 videos
8 - Other other defects
Other · 7 videos
7 Mixed bucket - Cladding drainage cavity, sealing, and opening flashing defects
Cladding render brickwork · 5 videos
6 - Missing or non-compliant doorway and perimeter waterstops
Waterproofing wet areas · 4 videos
6 - Active Shower Leaks and Subfloor Water Penetration
Waterproofing wet areas · 5 videos
5 - Defective or missing horizontal cladding joints and flashings
Cladding render brickwork · 2 videos
5 - Defective, retrofit, or missing wet area door waterstops
Waterproofing wet areas · 4 videos
5 - Deficient door threshold upstands and waterstops
Waterproofing wet areas · 5 videos
5 - Incomplete, patchy, or unfinished painting
Finishes painting tiling · 5 videos
5 - Other waterproofing wet areas defects
Waterproofing wet areas · 4 videos
5 Mixed bucket - Unsealed cladding joints, penetrations, and junctions
Cladding render brickwork · 4 videos
5 - Bushfire attack level (BAL) compliance failures and perimeter gaps
Cladding render brickwork · 3 videos
4 - Floor falls and levels (uneven, negative, or excessive falls)
Waterproofing wet areas · 3 videos
4 - Improper wall support and non-compliant framing layout
Structural framing · 3 videos
4 - Missing balustrades and edge protection
Stairs balustrades decks · 3 videos
4 - Moisture ingress, water damage, and timber swelling
Finishes painting tiling · 4 videos
4 - Stormwater sump, downpipe, and tank drainage issues
Plumbing · 4 videos
4 - Balcony Membrane Application, Junctions & Terminations
Waterproofing wet areas · 3 videos
3 - Combined tiling, painting, and fitting defects
Finishes painting tiling · 3 videos
3 - Defective joinery and cabinetry installation
Finishes painting tiling · 2 videos
3 - Defective or missing waterstop angles and threshold drainage
Waterproofing wet areas · 3 videos
3 - Inadequate panel clearance to ground, dirt, or openings
Cladding render brickwork · 3 videos
3 - Paint overspray on fixtures and surrounding surfaces
Finishes painting tiling · 3 videos
3 - Window Flashings and Openings
Cladding render brickwork · 3 videos
3 - Window Opening, Lintel, Trim and Ground Clearance Issues
Cladding render brickwork · 3 videos
3 - Complete absence of waterproofing membrane
Waterproofing wet areas · 2 videos
2 - Facade alignment deviation from plans
Cladding render brickwork · 2 videos
2 - Membrane and Basement Drainage System Failures
Drainage stormwater · 2 videos
2 - Missing lintel beam tie-down strapping
Structural framing · 2 videos
2 - Missing or inadequately supported stair landing
Stairs balustrades decks · 2 videos
2 - Painting, overspray, and finishing defects
Finishes painting tiling · 2 videos
2 - Shower Screen & Trim Leaks
Waterproofing wet areas · 2 videos
2 - Spoon drain non-compliance causing ponding and dampness
Drainage stormwater · 1 video
2 - Parapet capping overhang and window flashing defects
Roofing · 1 video
1 Seen once