Inspection Library

Cladding render brickwork

Defective, unsealed, or bridged articulation and expansion joints

9 examples in 4 videos 6 major 3 minor

What it is

Masonry articulation joints do not extend full height through window openings and are filled solid with mortar rather than flexible backing and mastic. The absence of proper expansion relief has caused adjacent masonry cracking.

The vertical articulation joint does not align properly with the window edge and terminates prematurely partway up the wall. Failure to carry the control joint through the full height prevents proper structural movement.

Engineering drawings specifying a 12 mm backing rod, mastic sealant, and cover moulding alongside window openings were ignored. Windows were installed hard up against the masonry joints across the property.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Structural framingWindows doors