Defective, unsealed, or bridged articulation and expansion joints
What it is
Masonry articulation joints do not extend full height through window openings and are filled solid with mortar rather than flexible backing and mastic. The absence of proper expansion relief has caused adjacent masonry cracking.
The vertical articulation joint does not align properly with the window edge and terminates prematurely partway up the wall. Failure to carry the control joint through the full height prevents proper structural movement.
Engineering drawings specifying a 12 mm backing rod, mastic sealant, and cover moulding alongside window openings were ignored. Windows were installed hard up against the masonry joints across the property.
Standards
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Structural framingWindows doors
Video examples
- Award-Winning Builder's $600K Flop? A Queensland Inspection Shocker! 16:08 majorDiscontinuous articulation joint and mortar bridging in brickwork
- I Reveal $900K Home Horror: NSW Building Inspection Gone Wrong! 16:45 majorMisaligned and incomplete masonry articulation joint
- Is The NSW Construction Industry A Shemozzle? 3:18 minorOmission of articulation joint backing rod and sealant at window openings
- Is The NSW Construction Industry A Shemozzle? 4:24 majorArticulation joints failing to extend full wall height
- Is The NSW Construction Industry A Shemozzle? 6:53 minorDefective and unsealed articulation joints
- Cranbourne West Exposé: Revisiting the Construction Catastrophe 12:51 majorMetal flashing bridging and restricting brickwork articulation joint
- Cranbourne West Exposé: Revisiting the Construction Catastrophe 15:33 majorExpansion joint filled with solid render rather than flexible sealant
- Cranbourne West Exposé: Revisiting the Construction Catastrophe 23:46 minorUnsealed articulation and foam movement joints on external wall
- Cranbourne West Exposé: Revisiting the Construction Catastrophe 32:03 majorOpen expansion joint exposing timber framing and restricted window articulation