Cladding render brickwork

Excessive brickwork overhang at slab edge

13 examples in 10 videos 13 major

What it is

Expanding foam was improperly used beneath a significant brick veneer overhang where structural support is required. The exposed foam is degrading under ultraviolet exposure without providing code-compliant masonry support.

Loose timber offcuts and non-structural mortar were placed under overhanging masonry rather than engineered structural grout. Plywood and timber packers are structurally inadequate and subject to rot when supporting external brickwork.

The brick veneer overhangs the concrete slab edge by approximately 120 mm, leaving the masonry unsupported. This extreme overhang grossly exceeds permissible limits and compromises wall stability.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Drainage stormwaterFootings slabStructural framingWindows doors