Inadequate panel clearance to ground, dirt, or openings
What it is
The lower cladding only has 5 mm of vertical clearance, and the fixings used are non-galvanised Class 2 nails instead of the required corrosion-resistant Class 3 fasteners. This invalidates the manufacturer's warranty and causes premature rust staining.
Wall cladding panels were installed directly into soil, and render texture was applied straight over spray foam and corner angle without a proper base coat.
Autoclaved aerated concrete wall panels on an opening exceeding 3.6 metres were installed directly against the frame without the required 2 to 3 mm clearance. The lack of relief causes localized stress and external surface cracking.
Standards
- AS 3566.2 Suggested reference, unverified
- AS 4773.2 Suggested reference, unverified
- CSR Hebel Design Guide Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Site works landscapingWindows doors
Video examples
- I Inspected A Bankrupted Builder’s Project… 20:02 majorNon-compliant cladding ground clearance and non-galvanised fasteners
- Cranbourne West Exposé: Revisiting the Construction Catastrophe 16:00 majorSubstrate panel embedded in dirt and render texture over spray foam
- Buying a Home in Australia? Watch This First to Avoid Costly Mistakes! 13:06 minorNo clearance gap between AAC panel and wide door opening