Missing Z-flashing at balcony and wall cladding junctions
What it is
Balcony wall cladding terminates directly behind the floor tiles without a protective Z-flashing, permitting trapped drainage water to penetrate behind tiles and compromise waterproofing.
The underside of the polystyrene cladding panels above the first-floor balcony lacks flashings, leaving exposed foam vulnerable to moisture uptake.
Axon cladding panels terminate directly behind the balcony tiles without a Z-flashing. Without proper flashing, moisture draining behind the cladding cannot discharge safely onto the balcony surface.
Standards
- AS 4654.2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Stairs balustrades decksWaterproofing wet areas
Video examples
- $1M Home Disaster! This Builder’s Mistakes Will SHOCK You! 12:53 majorAbsence of Z-flashing where balcony cladding meets tiled surface
- $1M Home Disaster! This Builder’s Mistakes Will SHOCK You! 15:00 majorUnflashed bottom edges on polystyrene balcony cladding
- Cranbourne West Exposé: Revisiting the Construction Catastrophe 5:28 majorMissing Z-flashing at base of wall cladding over balcony junction