- Spot-fixing and insufficient tile adhesive coverage
Finishes painting tiling · 16 videos
21 - Parapet capping and flashings defects
Cladding render brickwork · 8 videos
9 - Movement and control joint defects in Hebel and cladding
Cladding render brickwork · 5 videos
8 - Other footings slab defects
Footings slab · 8 videos
8 Mixed bucket - Other drainage stormwater defects
Drainage stormwater · 6 videos
7 Mixed bucket - Defective vertical membrane termination heights and upstands
Waterproofing wet areas · 6 videos
6 - Balcony Overflow & Drainage Provisions
Waterproofing wet areas · 5 videos
5 - Defective beam and column connections
Structural framing · 4 videos
5 - Defective internal wet area waterproofing membranes and detailing
Waterproofing wet areas · 4 videos
5 - Deficient door threshold upstands and waterstops
Waterproofing wet areas · 5 videos
5 - Floor level tolerance deviations
Finishes painting tiling · 5 videos
5 - Missing balcony tile movement/expansion joints
Finishes painting tiling · 4 videos
5 - Missing or non-compliant balcony overflow provision
Drainage stormwater · 5 videos
5 - Other finishes painting tiling defects
Finishes painting tiling · 5 videos
5 Mixed bucket - Other waterproofing wet areas defects
Waterproofing wet areas · 4 videos
5 Mixed bucket - Balcony substrate preparation and detailing defects
Waterproofing wet areas · 3 videos
4 - Beam and ceiling frame deflection and sagging
Structural framing · 3 videos
4 - Downpipe spreader discharging onto flashings
Roofing · 4 videos
4 - Floor falls and levels (uneven, negative, or excessive falls)
Waterproofing wet areas · 3 videos
4 - Insufficient falls and drainage ponding
Waterproofing wet areas · 4 videos
4 - Missing or defective balcony overflows and penetrations
Waterproofing wet areas · 2 videos
4 - Missing or Defective Column Support and Omission
Structural framing · 3 videos
4 - Penetrations compromising waterproof membrane
Waterproofing wet areas · 4 videos
4 - Subfloor bearer support and span defects
Structural framing · 4 videos
4 - Substandard substrate preparation and surface defects
Waterproofing wet areas · 4 videos
4 - Balcony and Terrace Drain Sizing and Structural Support Defects
Drainage stormwater · 3 videos
3 - Capping flashing missing anti-capillary breaks
Roofing · 2 videos
3 - Defective or missing waterstop angles and threshold drainage
Waterproofing wet areas · 3 videos
3 - Defective, loose, or missing fasteners in joist hangers
Structural framing · 3 videos
3 - Flashing failures and resulting water ingress
Waterproofing wet areas · 3 videos
3 - Hollow, drummy, or debonded tiles and screed
Finishes painting tiling · 2 videos
3 - Missing or defective bond breakers and fillet joints
Waterproofing wet areas · 3 videos
3 - Missing Z-flashing at balcony and wall cladding junctions
Cladding render brickwork · 2 videos
3 - Non-compliant or missing balcony overflow drainage devices
Waterproofing wet areas · 2 videos
3 - Omitted or inadequate structural connections and fixings
Structural framing · 2 videos
3 - Subfloor Earth Cut, Grading, and Runoff Issues
Site works landscaping · 2 videos
3 - Active structural water penetration
Waterproofing wet areas · 2 videos
2 - Balcony Moisture Ingress & Management
Waterproofing wet areas · 2 videos
2 - Balcony Penetrations & Spigot Detailing
Waterproofing wet areas · 2 videos
2 - Balcony Sub-tile Drainage & Efflorescence
Waterproofing wet areas · 1 video
2 - Complete absence of waterproofing membrane
Waterproofing wet areas · 2 videos
2 - Damaged screed, pedestals, and paver tiles
Waterproofing wet areas · 1 video
2 - Defective Subfloor Beam Supports, Mounts, and Bearers
Structural framing · 1 video
2 - Embedded cladding and missing drainage details
Waterproofing wet areas · 2 videos
2 - HVAC and appliance exhaust flue discharge defects
Plumbing · 2 videos
2 - Inadequate structural load capacity of decks and balconies
Structural framing · 2 videos
2 - Internal Balcony / Canopy Drainage Lacking Sump and Overflow
Roofing · 2 videos
2 - Non-box-gutter overflow deficiencies
Roofing · 1 video
2 - Non-compliant and uncertified structural steel members
Structural framing · 1 video
2 - Overflow discharging directly onto balcony surface
Drainage stormwater · 2 videos
2 - Subfloor framing sagging and unauthorised alterations
Structural framing · 1 video
2 - Climbable horizontal transom on openable high window
Windows doors · 1 video
1 Seen once - Missing substrate control and expansion joints
Waterproofing wet areas · 1 video
1 Seen once - Omission of subdeck cross-bracing
Structural framing · 1 video
1 Seen once