Parapet capping and flashings defects
What it is
The pressure flashing fixings exceed the maximum allowable spacing of 100 mm, leaving the installation unsecured.
Parapet and wall junctions rely solely on silicone sealant rather than having metal capping or flashing installed. The sealant is already peeling away, leaving open avenues for water ingress.
The horizontal Z-flashing at the bottom edge of the wall cladding lacks an anti-capillary break. Capillary suction can draw rainwater up and over the upstand into the building envelope.
Standards
- AS 1562.1 Suggested reference, unverified
- AS 3566.2 Suggested reference, unverified
- AS 4654.2 Suggested reference, unverified
- Guide to Standards and Tolerances Suggested reference, unverified
- HB 39 Suggested reference, unverified
- Hebel Design and Installation Guide Suggested reference, unverified
- NCC Vol 2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Finishes painting tilingRoofingStairs balustrades decksStructural framingWaterproofing wet areas
Video examples
- Unbelievable! Building Surveyor Approved This... 3:54 minorPressure flashing fixings spaced more than 100 mm
- Off The Plan Disaster Revealed! 33:50 majorUncapped parapet joint relying on failing sealant
- I Uncovered a $1.1M NSW Building Catastrophe 9:20 majorMissing anti-capillary break on cladding Z-flashing
- I Uncovered a Nightmare: Inside the ~$2 Million Townhouses of West Melbourne 25:14 majorNon-compliant U-profile capping trapping water behind cladding
- These Units That Shouldn’t Have Been Signed Off.. 6:02 majorMissing capping and unsealed cut edges on Hebel panels
- These Units That Shouldn’t Have Been Signed Off.. 18:01 minorUnsealed flashing upstands and severe flooring level deviation
- Cranbourne West Exposé: Revisiting the Construction Catastrophe 3:31 majorNon-compliant balcony parapet capping without upstand or pressure flashing
- I Unraveled a $750K Construction Disaster: NSW Build Exposed! 23:09 minorInsufficient parapet capping overhang on balcony balustrade
- Buying a Home in Australia? Watch This First to Avoid Costly Mistakes! 10:18 majorWall cladding fails to achieve minimum 50 mm flashing lap