Window Opening, Lintel, Trim and Ground Clearance Issues
What it is
The window sill and lintel reveals are unevenly tapered, varying significantly in dimension across the opening. Additionally, the lintel is approximately 8 millimetres out of level.
PermaTimber cladding was cut and butted directly against window frames without the required perimeter trims. Omitting these trims violates manufacturer installation guidelines and leaves raw, poorly cut edges exposed.
Installed aluminium windows do not match the approved window schedule dimensions. Additionally, the external cladding lacks ground clearance and is buried directly in soil, violating manufacturer specifications.
Standards
- AS 4773.2 Suggested reference, unverified
- Guide to Standards and Tolerances Suggested reference, unverified
- Manufacturer instructions Suggested reference, unverified
- NCC Vol 2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- Buyer Beware! 0:33 minorTapered window reveal and out-of-level lintel
- I Inspected Her Brand New Home… It’s Worse Than It Looks 5:09 minorMissing window perimeter finishing trims on composite cladding
- Worst Builder 2024 End Game! 17:37 majorNon-conforming window dimensions and cladding buried in ground