Inspection Library

Drainage stormwater

Box gutter and rainhead overflow provision defects

4 examples in 4 videos 4 major

What it is

The lower box gutter accepts concentrated stormwater discharge from an upper roof via a downpipe without having an emergency overflow device installed. This creates a severe risk of internal flooding should the rainhead or outlet become blocked.

Balcony pod drainage with a box gutter combined the overflow and the main drainage outlet into a single line directed into a rainhead rather than discharging the overflow freely to the open atmosphere. Connecting the overflow directly to the stormwater piping conceals blockages and violates plumbing standards.

The box gutter overflow system provides no visible outlet discharging to the atmosphere. It appears connected directly into stormwater lines, defeating its fail-safe overflow function.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

PlumbingRoofingWaterproofing wet areas

Video examples