- Box gutter and sump overflow deficiencies
Roofing · 16 videos
28 - Missing or Defective Shower Waterstop Angles
Waterproofing wet areas · 13 videos
18 - Parapet capping inadequate slope or fall
Roofing · 12 videos
14 - Missing or defective shower waterstop and enclosure barrier
Waterproofing wet areas · 8 videos
12 - Box Gutter and Sump Overflow Provisions and Non-Compliant Devices
Roofing · 6 videos
11 - Exposed and hazardous electrical wiring
Electrical · 9 videos
11 - Disconnected or Improper Roof Downpipe Discharge
Drainage stormwater · 9 videos
9 - Non-conforming or Counterfeit Rainheads
Roofing · 8 videos
9 - Waterstop disconnection from flashing and membrane termination defects
Waterproofing wet areas · 6 videos
9 - Bathroom & Wet Area Doorway Threshold Waterstops
Waterproofing wet areas · 7 videos
8 - Downpipe spreader unsealed, missing, or physical installation defects
Roofing · 6 videos
8 - Other footings slab defects
Footings slab · 8 videos
8 Mixed bucket - Box gutter and sump overflow arrangement non-compliant
Roofing · 4 videos
7 - Box Gutter to Rainhead Connection and Sealing Defects
Roofing · 5 videos
7 - Missing or Defective Bathroom and Doorway Waterstops
Waterproofing wet areas · 5 videos
7 - Other drainage stormwater defects
Drainage stormwater · 6 videos
7 Mixed bucket - Other insulation energy defects
Insulation energy · 7 videos
7 Mixed bucket - Other other defects
Other · 7 videos
7 Mixed bucket - Roof and wall flashing defects
Roofing · 6 videos
7 - Active water leaks and waterproofing failure
Waterproofing wet areas · 5 videos
6 - Electrical cables in direct contact with plumbing and gas pipes
Electrical · 6 videos
6 - Shower Hob & Shower Waterstop Non-Compliance
Waterproofing wet areas · 5 videos
6 - Undersized or non-compliant roof sump dimensions
Roofing · 3 videos
6 - Active Shower Leaks and Subfloor Water Penetration
Waterproofing wet areas · 5 videos
5 - Balcony Overflow & Drainage Provisions
Waterproofing wet areas · 5 videos
5 - Box Gutter Discharging Directly Without Proper Termination or Sump
Roofing · 4 videos
5 - Box gutter overflow positioning, sizing, or non-compliant geometry
Roofing · 3 videos
5 - Box gutter width or depth undersized
Roofing · 2 videos
5 - Corroded or non-compliant roof fasteners
Roofing · 5 videos
5 - Defective internal wet area waterproofing membranes and detailing
Waterproofing wet areas · 4 videos
5 - Defective or Missing Downpipe Spreaders
Drainage stormwater · 5 videos
5 - Downpipe spreader discharging into valleys or prohibited elements
Roofing · 4 videos
5 - Exhaust fans discharging into roof space without external ducting
Insulation energy · 4 videos
5 - Missing or defective flashing and capping
Roofing · 5 videos
5 - Other finishes painting tiling defects
Finishes painting tiling · 5 videos
5 Mixed bucket - Waterproofing failure causing active leaks, external efflorescence, or damage
Waterproofing wet areas · 4 videos
5 - Active Roof Leaks and Water Ingress to Ceilings
Roofing · 4 videos
4 - Blocked, sealed perimeter, or obstructed puddle flange drainage
Waterproofing wet areas · 4 videos
4 - Box gutter and rainhead overflow provision defects
Drainage stormwater · 4 videos
4 - Box gutter dimensional and sizing deficiencies
Roofing · 3 videos
4 - Box gutter discharging directly to outlet or unsealed rainhead without standard sump or overflow
Roofing · 3 videos
4 - Box gutter geometry, depth, upstand and fall deficiencies
Roofing · 3 videos
4 - Box gutter physical deformation, alignment, and ponding
Roofing · 3 videos
4 - Box gutter sump dimensions narrower than sole or undersized
Roofing · 4 videos
4 - Direct discharge of gutters or downpipes into eaves gutter
Roofing · 3 videos
4 - Downpipe spreader discharging onto flashings
Roofing · 4 videos
4 - Gutter slope, fall defect, and water ponding
Roofing · 4 videos
4 - Missing doors or windows / Incomplete installation at stage
Windows doors · 4 videos
4 - Penetrations compromising waterproof membrane
Waterproofing wet areas · 4 videos
4 - Subfloor insulation missing, fallen, or improperly installed
Insulation energy · 4 videos
4 - Sump, downpipe, and drainage defects
Roofing · 4 videos
4 - Unsealed and unwaterproofed wall and floor pipe penetrations
Waterproofing wet areas · 4 videos
4 - Balcony and Terrace Drain Sizing and Structural Support Defects
Drainage stormwater · 3 videos
3 - Bathroom wall tiling defects and bathtub installation
Finishes painting tiling · 3 videos
3 - Box gutter configuration and thermal expansion defects
Roofing · 3 videos
3 - Box gutter connection, fastening, and joint sealing defects
Roofing · 3 videos
3 - Box gutter geometry, width, and directional defects
Roofing · 2 videos
3 - Box gutter sump and overflow non-compliant configuration or weir placement
Roofing · 3 videos
3 - Box gutter thermal movement and expansion joint omission
Roofing · 2 videos
3 - Comprehensive / Combined Roof Plumbing, Sump, and Flashing Non-Compliance
Roofing · 3 videos
3 - Cut or penetrated floor joists and trusses
Structural framing · 3 videos
3 - Defective joinery and cabinetry installation
Finishes painting tiling · 2 videos
3 - Direct gutter discharge, rainhead connections, and flashing ponding
Roofing · 3 videos
3 - Gutter and sump lacking structural support
Roofing · 3 videos
3 - Improper power outlet positioning near water or fixtures
Electrical · 3 videos
3 - Missing, uninstalled, or omitted shower puddle flanges
Waterproofing wet areas · 3 videos
3 - Non-Compliant External/Overflow Connections to Drainage System
Drainage stormwater · 3 videos
3 - Non-compliant or missing balcony overflow drainage devices
Waterproofing wet areas · 2 videos
3 - Paint overspray on fixtures and surrounding surfaces
Finishes painting tiling · 3 videos
3 - Parapet and roof capping missing anti-capillary breaks
Roofing · 3 videos
3 - Particleboard and Subfloor Rot and Moisture Deterioration
Structural framing · 3 videos
3 - Planter box waterproofing, falls, and drainage defects
Waterproofing wet areas · 1 video
3 - Rainhead overflow and connection defects
Roofing · 3 videos
3 - Roof covering turn-down and overhang defects
Roofing · 3 videos
3 - Shower Base Fall, Hob Construction and Drainage Defects
Waterproofing wet areas · 3 videos
3 - Valley and transition gutter installation issues
Roofing · 3 videos
3 - Balcony drainage failing to discharge to atmosphere
Drainage stormwater · 2 videos
2 - Box gutter discharging into eaves gutter
Drainage stormwater · 2 videos
2 - Box Gutter Sizing, Sump Capacity, and Upstand Dimensions
Roofing · 2 videos
2 - Box Gutter Structural Support and Expansion Movement
Roofing · 1 video
2 - Compromised roof penetrations, flues, and sumps
Roofing · 2 videos
2 - Defective penetration sealing and dektites
Roofing · 2 videos
2 - Direct, lateral, or side discharge from box gutter or sump
Roofing · 2 videos
2 - Downpipe, condensation drain, and flashing upstand defects
Roofing · 2 videos
2 - Drainage System Blocked or Fouled by Debris
Drainage stormwater · 2 videos
2 - Excavation and Sewer Clearance Footing Undermining
Footings slab · 2 videos
2 - General non-compliant drainage and discharge
Drainage stormwater · 2 videos
2 - High-capacity surface water overflow non-compliance
Drainage stormwater · 2 videos
2 - Inadequate Cover Depth Over Drainage/Stormwater Pipes
Drainage stormwater · 2 videos
2 - Inadequate roof flashing upstand height and fixing spacing
Roofing · 2 videos
2 - Inappropriate subsoil and strip drain discharge or connections
Drainage stormwater · 2 videos
2 - Insecure or improper air conditioning unit mounting
Other · 2 videos
2 - Missing or defective gutters causing drainage issues
Roofing · 2 videos
2 - Rainhead and Downpipe Discharge / Overflow Position
Roofing · 2 videos
2 - Rainhead overflow level and opening restrictions
Roofing · 1 video
2 - Roof and eaves gutter fall and drainage defects
Roofing · 1 video
2 - Roof Penetrations and Flashing Failures
Roofing · 2 videos
2 - Roof sheeting turn-down and pan detailing defects
Roofing · 2 videos
2 - Saddle truss inadequate support and connections
Structural framing · 2 videos
2 - Stormwater and Drainage Pipes Holding Water / Backfall
Drainage stormwater · 2 videos
2 - Sump substrate and structural underside support deficiencies
Roofing · 2 videos
2 - Unsupported roof sheets and missing support battens
Roofing · 1 video
2 - Defective planter box waterproofing and condensate drainage
Waterproofing wet areas · 1 video
1 Seen once - Gutter expansion joint missing or thermal deformation
Roofing · 1 video
1 Seen once - Sheet metal cutting damage and corrosion
Roofing · 1 video
1 Seen once - Substandard metalwork workmanship with excessive sealant
Roofing · 1 video
1 Seen once