Defective or Missing Downpipe Spreaders
What it is
Roof spreader pipes were installed without end caps and discharge water in reverse direction against the roof slope. This improper configuration prevents proper drainage across the lower roof sheets and breaches roofing standards.
The downpipe spreader discharges directly sideways across the lower roof rather than discharging correctly down the pitch of the receiving roof. This improper discharge direction increases the risk of water ingress and roof inundation.
Upper roof downpipes discharge concentrated rainwater onto lower roof areas without spreaders. Surface stormwater management during construction is completely absent, allowing uncontrolled runoff across roof coverings.
Standards
- AS 2870 Said in video
- AS 3566 Suggested reference, unverified
- AS/NZS 3500.3 Suggested reference, unverified
- HB 39 Said in videoSuggested reference, unverified
- NCC Vol 2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- "DREAM HOME" TO DISASTER: Why the QBCC is Failing Australia’s Homeowners 41:48 majorDefective downpipe spreaders discharging opposite to roof fall
- Luxury Apparent Handover #home #construction #renovation 1:08 minorNon-compliant downpipe spreader orientation
- I Hired Security to Do an Inspection: The Shocking Discovery the Builder Wanted Hidden! 23:18 minorMissing downpipe spreaders during construction
- I Climbed Into the Roof Nobody Checked Before They Bought 3:00 minorRoof valley discharges without required spreader or downpipe
- Home Inspection Disaster: Marong's Shemozzel Brickwork… 13:31 minorMissing downpipe spreader and non-compliant roof fasteners