Inspection Library

Drainage stormwater

Disconnected or Improper Roof Downpipe Discharge

9 examples in 9 videos 6 major 3 minor

What it is

Stormwater discharges directly against perimeter footings in non-compliance with foundation standards, already prompting cracking. Missing roof sarking and cladding secured merely with spray foam were also noted.

Rainwater drainage discharge points fail to provide the required 100 mm minimum vertical clearance above finished ground levels.

Temporary downpipes were left disconnected, letting stormwater saturate reactive clay soil immediately adjacent to the concrete foundation slab. This foundation wetting threatens reactive soil movement and differential foundation heave.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Cladding render brickworkFootings slabPlumbingRoofing

Video examples