Spoon drain non-compliance causing ponding and dampness
What it is
The concrete spoon drain collects water from leaking areas but terminates abruptly without connecting to a stormwater discharge point. A lack of fall towards the garage entrance creates extensive water ponding and threatens internal flooding.
The spoon drain continues around the rear units terminating into dead space, fostering persistent moisture and mold growth. As a result of this drainage failure, adjacent timber door frames and trims have begun rotting.
Standards
- AS/NZS 3500.3 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- I Inspected A Bankrupted Builder’s Project… 21:16 majorLevel spoon drain discharging nowhere and causing garage ponding
- I Inspected A Bankrupted Builder’s Project… 22:24 majorDiscontinuous spoon drain causing dampness and timber jamb rot