Electrical cables in direct contact with plumbing and gas pipes
What it is
Electrical wiring is left unclipped and loose inside the cavity, resting across plumbing water services. The cables are unsupported and trapped without required mechanical protection or separation.
Electrical wiring is routed in direct contact with metal water supply pipes and gas piping inside the ceiling space. Electrical and plumbing safety standards mandate an explicit minimum separation distance of 25 mm.
Electrical wiring throughout the roof cavity is disorderly and crosses directly over water pipework without adequate separation. This creates potential electrical safety and fire hazards.
Standards
- AS/NZS 3000 Said in videoSuggested reference, unverified
- AS/NZS 3500.2 Said in video
- AS/NZS 5601.1 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- Are Homebuyers Getting Scammed…We Returned to the $2M Disaster 3:57 majorUnsecured electrical cabling crossing plumbing
- $2.1 Million To Build & $250,000+ To Manage! 31:15 minorInadequate clearance between electrical cables, water pipes, and gas lines
- Caught on Cam: Cops Stop Inspection at Builder's Demand! 48:43 majorElectrical cables touching and crossing water pipework
- "DREAM HOME" TO DISASTER: Why the QBCC is Failing Australia’s Homeowners 20:15 majorElectrical cables in direct contact with water pipes and steel frame
- I Reveal $900K Home Horror: NSW Building Inspection Gone Wrong! 13:33 majorDirect contact between electrical cabling and gas piping
- Unbelievable! Building Surveyor Approved This... 23:18 majorElectrical cables crossing water pipes without required separation