Inspection Library

Finishes painting tiling

Spot-fixing and insufficient tile adhesive coverage

21 examples in 16 videos 19 major 2 minor

What it is

Tiles throughout the residence were installed using spot-fixing blobs rather than notched trowel spread and back-buttering. This installation technique breaches minimum wet-area adhesive coverage requirements, necessitating tile removal.

Adhesive or compound was applied using the non-compliant spot-fixing technique rather than full-coverage or notched trowelling. This requires complete removal and replacement.

The shower recess tiles were installed using spot-fixing rather than full adhesive bed coverage. This improper fixing technique leaves large voids behind tiles, leading to cracking, drumming, and membrane failure.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Cladding render brickworkStairs balustrades decksWaterproofing wet areas