What it is

The box gutter measures only thirty millimetres in depth at its upper end, well under the mandatory ninety-six millimetre depth for a three hundred millimetre gutter. This severely limits flow capacity and causes back-flooding.

The high-capacity overflow device fails to meet the minimum required weir length of 600 mm, measuring roughly 460 mm. The insufficient weir dimension severely limits flow capacity during storm events.

The box gutter measures only 150 mm wide, failing to satisfy the mandatory 200 mm minimum channel width standard. The restricted channel dimensions create high risk of overflow and internal water ingress.