Floor waste trap water seal exceeds depth limit
What it is
The measured water seal level in the floor waste gully sits approximately 1.9 m below the grate level, far deeper than the maximum allowable limit of 600 mm. This non-conforming trap depth occurs consistently across all bedroom ensuites.
Measurement of the floor waste water trap indicates a depth of approximately 800 mm, far exceeding the 600 mm maximum allowed. This non-compliant plumbing depth risks trap siphonage and sewer gas leakage.