Rainwater head and overflow drainage defects
What it is
The stormwater overflow outlet was configured to dump water directly onto the covered front porch floor. High-capacity discharge underneath an entry creates localized ponding and property flooding hazards.
The box gutter emergency overflow was piped into the back of a rain head downpipe rather than discharging freely to the open atmosphere. Overflows must discharge to open air where failures are immediately visible.
A downpipe spreader is not capped correctly to discharge rainwater in the direction of gutter flow, while surrounding roof corner flashings remain open and unsealed.
Standards
- AS 4654.2 Suggested reference, unverified
- AS/NZS 3500.3 Suggested reference, unverified
- HB 39 Said in video
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Cladding render brickworkDrainage stormwaterFinishes painting tilingRoofing
Video examples
- I Exposed Preston’s Worst Build: Police Called During Shocking Home Inspection! 49:23 majorHigh-capacity overflow discharging water directly under porch
- I Exposed Preston’s Worst Build: Police Called During Shocking Home Inspection! 57:45 majorOverflow pipe incorrectly routed to discharge into enclosed rain head
- I Uncovered a $1.1M NSW Building Catastrophe 9:49 minorInadequate rainwater spreader discharge and unsealed flashing
- If you’ve signed a contract in the last 7 days, watch this. 1:15 majorImproper penetration and continuous balcony overflow discharge
- The $5 Million Homebuyer's Tragic Story: How Site Inspections Uncovered a Nightmare 6:04 majorRainhead outlet not configured for total drainage