Box gutter and sump overflow arrangement non-compliant
What it is
The installed rainheads lack the required 25 mm depth drop below the box gutter invert. Additionally, non-compliant overflow solutions were utilised instead of leaving rainheads properly configured.
The high-capacity overflow sump setup does not satisfy minimum standard dimensions for width and depth. The outlets are also improperly installed and non-compliant.
The lower porch box gutter features only a single outlet with no overflow provision installed. In addition, the connected rainhead installation is unconventional and non-compliant.
Standards
- AS/NZS 3500.3 Said in videoSuggested reference, unverified
- HB 39 Said in video
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- VMIA Insurance Inconsistencies: A Deep Dive into a Shangri-La Construction Inspection Report 16:34 majorRainhead overflow arrangement non-compliant
- VMIA Insurance Inconsistencies: A Deep Dive into a Shangri-La Construction Inspection Report 18:14 majorHigh-capacity overflow sump non-compliant
- Buying a Home in Australia? Watch This First to Avoid Costly Mistakes! 1:27 majorBox gutter lacks overflow device and compliant rainhead
- Buying a Home in Australia? Watch This First to Avoid Costly Mistakes! 2:05 majorBox gutter discharges directly to outlet without sump or overflow
- Buying a Home in Australia? Watch This First to Avoid Costly Mistakes! 7:15 majorSump undersized with non-compliant overflow configuration
- Building Nightmares Unveiled: A Homeowner's Harrowing Journey Through Construction Chaos 30:00 majorNon-compliant circular overflow in box gutter sump
- The Shocking Truth: Builder Vanishes, Leaving Half-Finished Project... 16:00 majorNon-compliant box gutter upstand and sump overflow arrangement