Box Gutter and Sump Overflow Provisions and Non-Compliant Devices

11 examples in 6 videos 11 major

What it is

The high-capacity overflow device on the box gutter is incorrectly plumbed. Instead of spilling to the atmosphere externally, the overflow is plumbed into the drainage line.

Testing with water confirms the overflow outlet is connected directly to the primary drainage line. An overflow must spill independently to open air to avoid internal flooding.

The high-capacity overflow device and sole gap do not comply with standards, and the overflow outlet is undersized at 75 mm instead of at least 90 mm or 100 mm.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.