Box gutter connection, fastening, and joint sealing defects

3 examples in 3 videos 2 major 1 minor

What it is

The connection between the box gutter and the rainhead lacks a mechanical lap seam and relies purely on a bead of silicone. Thermal expansion and contraction will rupture the sealant and admit water behind the external cladding.

Metal apron and box gutter flashings were installed without continuous silicone sealant along laps, leaving wide 100 mm unbonded voids where 40 mm maximum spacing is mandated. Fasteners are under-rated Class 2 instead of external Class 3.

A roof box gutter was terminated into a rainhead without mechanical fixings. Omitting mechanical fasteners creates a loose junction prone to displacement and storm water leakage.