Box Gutter Discharging Directly Without Proper Termination or Sump
What it is
The upper roof drainage features a non-compliant box gutter installation alongside an upper downpipe discharging directly onto a valley. Discharging concentrated runoff over roof sheets and valleys risks significant water ingress into the dwelling.
The box gutters on units 3 and 4 discharge directly into eaves gutters rather than terminating at a sump or rainhead. The slope also changes inappropriately along the run.
Box gutters must terminate into a sump or rainhead rather than draining straight into eaves gutters. Rectification requires reframing, altering falls, or introducing compliant sumps.
Standards
- AS/NZS 3500.3 Said in videoSuggested reference, unverified
- HB 39 Said in video
- NCC Vol 2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.