Box gutter physical deformation, alignment, and ponding
What it is
The metal box gutter was deformed and kicked inward with boots on-site rather than being accurately folded in a sheet metal pan brake. This distortion restricts cross-sectional flow and causes ponding.
A box gutter changes direction into another box gutter with inconsistent gradient, violating AS/NZS 3500.3 restrictions. Adjacent concrete roof tiles are neither nailed nor clipped, allowing them to slide freely out of position.
A waterproofed box gutter narrows in width from over 300 mm and lacks uniform slope, causing stagnant stormwater ponding. In addition, the gutter discharges directly into an inline droptube rather than a conforming sump or rain head.
Standards
- AS 2050 Suggested reference, unverified
- AS/NZS 3500.3 Said in videoSuggested reference, unverified
- HB 39 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- I Exposed Preston’s Worst Build: Police Called During Shocking Home Inspection! 41:43 majorBox gutter crudely kicked and deformed into place
- I Inspected a Billionaire’s Mansion 32:16 majorBox gutter changes direction with non-constant slope and unsecured tiles
- I Inspected a Billionaire’s Mansion 33:52 majorWater ponding in box gutter due to narrowing and inconsistent fall
- I Hired Security to Do an Inspection: The Shocking Discovery the Builder Wanted Hidden! 4:18 majorNon-compliant box gutter changes of direction and sump overflows