Box Gutter Structural Support and Expansion Movement
What it is
The lower roof box gutter lacks continuous substrate support along its entire length. This creates substantial deformation risk and unsafe footing during maintenance.
The metal box gutter installation contains no expansion joints along its run. Metal gutters expand and contract with temperature changes, causing buckling or seam failure without joints.
Standards
- AS/NZS 3500 Said in video
- AS/NZS 3500.3 Said in videoSuggested reference, unverified
- HB 39 Said in video
- NCC Said in video
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- Off The Plan Disaster Revealed! 12:25 majorLack of continuous structural support under box gutter
- Off The Plan Disaster Revealed! 20:15 majorMissing thermal expansion joints along box gutter run