2 examples in 1 video 2 major

What it is

The lower roof box gutter lacks continuous substrate support along its entire length. This creates substantial deformation risk and unsafe footing during maintenance.

The metal box gutter installation contains no expansion joints along its run. Metal gutters expand and contract with temperature changes, causing buckling or seam failure without joints.