Box gutter sump dimensions narrower than sole or undersized

4 examples in 4 videos 3 major 1 minor

What it is

The roof sump fails to achieve the mandatory 600 mm minimum length for a high-capacity overflow configuration. It also incorporates an unauthorised reverse pop fitting without any engineering performance solution.

The box gutter sump fails to meet the minimum 400 mm length requirement and does not match the gutter width. Furthermore, the overflow device was placed in the wrong position.

The sump is approximately 35 mm narrower than the full width of the box gutter it serves. It has also been shifted off-centre without the necessary performance solution.