Comprehensive / Combined Roof Plumbing, Sump, and Flashing Non-Compliance
What it is
A rainwater spreader pipe fails to discharge towards the downpipe. In addition, the rainwater head and sump overflow discharge straight into the drainage line instead of to the atmosphere.
Multiple roof elements are non-compliant, including the flashings, rain heads, spreaders, and condensation drainage lines. A box gutter reduction was also improperly installed.
The roof drainage discharges into an intermediary sump before discharging to the rainhead, which constitutes a non-compliant configuration. Additionally, the sloping roof apron and perimeter flashings are incorrectly installed.
Standards
- AS/NZS 3500.3 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- I Investigated the Worst Builder of 2025 — The Evidence Is Unreal 13:50 majorNon-compliant spreader discharge and combined sump overflow
- Building in Australia? 0:00 majorNon-compliant roof plumbing, flashings, box gutters, and spreaders
- Builders' Shocking Revelation: From Inspection to Rectification 15:21 majorNon-compliant roof discharge, sump, apron, and flashing