Direct gutter discharge, rainhead connections, and flashing ponding
What it is
Stormwater runoff from an upper box gutter discharges directly into a standard eaves gutter rather than into an appropriate sump or rainhead. This connection arrangement breaches stormwater drainage provisions.
A box gutter freely discharges into a rainhead without being properly lapped, joined, or mechanically fastened. The joint fails required fastener spacing and lap sealing standards.
The area around the box gutter sump exhibits poor workmanship with multiple redundant, uncoordinated flashings layered over each other. The basin holds standing water with no secondary overflow provision installed.
Standards
- AS/NZS 3500.3 Said in video
- HB 39 Said in videoSuggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- I inspected a $500K Dangerous Extension 5:48 majorBox gutter discharging directly into eaves gutter without sump or rainhead
- This Homeowner Thought He Found a $3m Dream Home … 19:42 majorImproper connection and sealing of box gutter to rainhead
- The Ghost Builder & the Haunted Home: Unmasking Construction Nightmares 5:57 majorMultiple haphazard flashing layers and ponding around box gutter sump