Inspection Library

Roofing

Gutter slope, fall defect, and water ponding

4 examples in 4 videos 3 major 1 minor

What it is

The lower roof box gutter exhibits a negative fall rather than the required 1 in 100 gradient, causing rainwater ponding. In addition, the gutter discharges directly into two raw outlets without a sump or rainhead.

Excessive water ponds in the box gutter sole because adequate continuous fall toward the outlet has not been achieved. Standing water accelerates material corrosion and risks overflowing during rain events.

Up to 25 mm of ponding water was measured in the gutter due to incorrect fall away from the outlet and construction debris, creating a damming effect.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Drainage stormwaterPlumbing

Video examples