What it is
The lower roof box gutter exhibits a negative fall rather than the required 1 in 100 gradient, causing rainwater ponding. In addition, the gutter discharges directly into two raw outlets without a sump or rainhead.
Excessive water ponds in the box gutter sole because adequate continuous fall toward the outlet has not been achieved. Standing water accelerates material corrosion and risks overflowing during rain events.
Up to 25 mm of ponding water was measured in the gutter due to incorrect fall away from the outlet and construction debris, creating a damming effect.