Non-box-gutter overflow deficiencies

2 examples in 1 video 1 major 1 minor

What it is

The planter box gutter overflow system fails capacity standards, discharging runoff water straight onto external face masonry. Constant watering will degrade and stain the brickwork.

The upper enclosed balcony has no overflow provision installed. In a severe storm or gutter blockage, water will back up and flood internal habitable areas.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Cladding render brickworkDrainage stormwaterStairs balustrades decks