Inspection Library

Roofing

Rainhead overflow and connection defects

3 examples in 3 videos 3 major

What it is

Box gutters project directly into rainheads without continuous folding, perimeter stitching at 40 mm centres, or proper flashing. The underside joints rely solely on silicone sealant rather than an approved watertight lap.

First-floor balcony rainhead installations lack visible overflow relief points discharging to the open air, creating risk of concealed water backup.

The rainhead overflow weir is not positioned 25 mm below the sole of the box gutter. Additionally, the box gutter discharge point is poorly sealed to the rainhead with silicone.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Drainage stormwaterPlumbing

Video examples