Inspection Library

Roofing

Roof and wall flashing defects

7 examples in 6 videos 4 major 3 minor

What it is

Wall apron flashing at the roof junction was installed as a single piece and secured using inappropriate internal plasterboard screws instead of approved weather-resistant exterior fasteners. This inadequate fixing will deteriorate and allow water ingress.

A roof flashing top cover is missing, and roofer used internal plasterboard screws covered merely with silicone to fasten external joints. The spreader also discharges water backwards against the roof fall.

The wall-to-roof flashing has broad gaps that allow daylight and the exterior roof to be seen clearly from inside the dwelling. The building envelope is completely unsealed against weather.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Cladding render brickworkPlumbingWaterproofing wet areas