Roof covering turn-down and overhang defects
What it is
Roofing sheet ends were not turned down into the gutter as mandated by installation manuals. Construction rubbish, instant noodle packaging, and electrical plates were also discarded across the roof.
Roof tiles project over 100 mm into the box gutter, completely hiding the gutter channel and sump from view. This exceeds the maximum allowable 65 mm projection specified under the standards and prevents inspection and clearance.
Roof metal sheets overhang into the box gutter by 105 mm to 120 mm, far exceeding permitted installation tolerances. Excessive sheet overhang restricts gutter inspection, cleaning, and free water flow into the channel.
Standards
- AS/NZS 3500.3 Suggested reference, unverified
- Guide to Standards and Tolerances Said in videoSuggested reference, unverified
- HB 39 Said in videoSuggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- I Uncovered a Nightmare: Inside the ~$2 Million Townhouses of West Melbourne 34:47 minorRoof sheets not turned down at gutter edge and junk on roof
- I Inspected A Bankrupted Builder’s Project… 9:20 minorRoof tiles excessive overhang concealing box gutter
- 2023's Most Costly Building Mistake… 10:53 minorExcessive roof sheeting overhang into box gutters