Roof sheeting turn-down and pan detailing defects
What it is
Metal roof sheet ends are not turn-up or stop-ended folded, allowing water ponding. Additionally, an upper catchment spreader pipe fails to discharge in the direction of gutter flow.
Roof sheeting discharging away from the box gutter lacks the requisite vertical edge turn-down mandated by the standards. Water tracks backwards along the sheet undersides during rain events and discharges directly into ceiling cavities.
Standards
- AS 1562.1 Suggested reference, unverified
- AS/NZS 3500.3 Suggested reference, unverified
- HB 39 Said in videoSuggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Drainage stormwaterPlumbingWaterproofing wet areas
Video examples
- I Investigated the Worst Builder of 2025 — The Evidence Is Unreal 11:56 majorUnfolded roof sheeting pans and misdirected spreader pipe
- 2023's Most Costly Building Mistake… 29:25 majorInadequate roof sheet turn-down causing capillary back-flow into building