Sump, downpipe, and drainage defects

4 examples in 4 videos 4 major

What it is

The downpipe has rusted through creating a substantial hole, while the internal sump is unsupported and required structural steel members to be compromised during installation. Water leakage has damaged switchboard wiring and structural timber frames.

The mechanical pop-rivet fasteners connecting the sump to the box gutter exceed the 40 mm maximum spacing allowance. Insufficient stitching allows stormwater to penetrate the seam despite the application of topical sealant.

The upper roof box gutter sump is undersized at approximately 300 mm rather than meeting high-capacity deemed-to-satisfy requirements. Additionally, the roof sarking does not terminate properly into the box gutter, and vertical flashing terminations are non-compliant.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Cladding render brickworkDrainage stormwaterPlumbingStructural framing