Sump, downpipe, and drainage defects
What it is
The downpipe has rusted through creating a substantial hole, while the internal sump is unsupported and required structural steel members to be compromised during installation. Water leakage has damaged switchboard wiring and structural timber frames.
The mechanical pop-rivet fasteners connecting the sump to the box gutter exceed the 40 mm maximum spacing allowance. Insufficient stitching allows stormwater to penetrate the seam despite the application of topical sealant.
The upper roof box gutter sump is undersized at approximately 300 mm rather than meeting high-capacity deemed-to-satisfy requirements. Additionally, the roof sarking does not terminate properly into the box gutter, and vertical flashing terminations are non-compliant.
Standards
- AS/NZS 3500.3 Suggested reference, unverified
- HB 39 Suggested reference, unverified
- Weathertex Installation Manual Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Cladding render brickworkDrainage stormwaterPlumbingStructural framing
Video examples
- I Inspected Troy Candy's Multi-Million Dollar Home: Shocking Finds! 25:47 majorPerforated rusted downpipe and unsupported sump cutting steel framing
- I Inspected A Bankrupted Builder’s Project… 14:25 majorExcessive fastener spacing on box gutter sump connection
- This Homeowner Thought He Found a $3m Dream Home … 5:14 majorNon-compliant roof sump dimensions and missing sarking turnover
- These Units That Shouldn’t Have Been Signed Off.. 16:40 majorMissing gutter sumps and unsealed cladding junctions against brickwork