Valley and transition gutter installation issues
What it is
Water discharge from the roof valley gutter ponds in a localized dip, causing storm run-off to backcharge under the tiles and sarking. This defective design causes water to migrate down the lining and stain the eaves.
Ridge cappings are improperly fastened, valleys are defective, and the box gutter is non-compliant. Additionally, the roof fall measures 1.6 degrees against the mandatory 2.0-degree minimum slope, requiring batten reframing.
An intermediate box gutter was installed directly across an unbroken roof pitch without any transverse weather flashing. Rainwater blown by wind drives up and under the upper sheet crests, spilling directly into the ceiling void.
Standards
- AS 1562.1 Suggested reference, unverified
- AS 2050 Suggested reference, unverified
- AS/NZS 3500.3 Suggested reference, unverified
- HB 39 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- What Does $335K Build in Bendigo? Shocking Findings! 11:01 majorValley gutter detail causes backcharging and eaves leak
- Top 5 Real Life Home Inspection Encounters… 2:32 majorSubstandard ridge capping, valley installation, inadequate pitch, and box gutter
- 2023's Most Costly Building Mistake… 33:58 majorUnflashed broken roof pitch transition with intermediate box gutter