Missing movement or control joints in balcony flooring substrate
What it is
The compressed fibre cement sheet flooring spans approximately 7 metres without an expansion control joint. Manufacturers and standards require a movement joint at 4.1 metres to prevent substrate cracking and membrane tearing.
A 6.3-metre balcony with staggered floor sheets was installed without any expansion or control joints. For staggered layouts, the manufacturer mandates intermediate control joints every 4.1 metres.
The balcony substrate spans 4.38 metres without the required movement joint at 4.2 metres specified by James Hardie. This lack of joint risks membrane rupture and water leaks from structural movement.
Standards
- AS 3958.1 Suggested reference, unverified
- James Hardie Scyon Secura Installation Manual Suggested reference, unverified
- NCC Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Finishes painting tilingStructural framingWaterproofing wet areas
Video examples
- I Inspected Australia's Best House… 8 Years Later 14:24 majorMissing movement joint in Scyon flooring sheet over 7 metres
- They Approved THIS?! Engineer Caught in Major Mistake! 21:24 minorMissing control joints across 6.3m balcony flooring