Non-compliant stair riser and going dimensions or variations
What it is
Stair treads measured 230 mm in depth, breaching the statutory minimum 240 mm going requirement. Undersized goings present significant slipping and tripping hazards.
Stair risers varied between 175 mm and 185 mm within the same flight. This 10 mm discrepancy exceeds the allowable 5 mm maximum variation limit across consecutive stairs.
Riser measurements varied between 175 mm and 190 mm, while goings ranged from 235 mm to 255 mm. Variations of up to 20 mm breach the 5 mm maximum tolerance limit.
Standards
- NCC Vol 2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Video examples
- I Uncovered a Nightmare: Inside the ~$2 Million Townhouses of West Melbourne 48:04 majorStairway tread going under minimum 240 mm dimension
- I Uncovered a Nightmare: Inside the ~$2 Million Townhouses of West Melbourne 48:39 majorUneven stair riser heights exceeding 5 mm variation limit
- I Uncovered a Nightmare: Inside the ~$2 Million Townhouses of West Melbourne 1:01:26 majorExcessive riser and going variations along stair flight
- This First-Time Homebuyer’s Nightmare Will Shock You! 8:16 majorNon-compliant single stair riser exceeding 200 mm height