Improper wall support and non-compliant framing layout
What it is
An external structural load-bearing wall containing critical bracing elements is directly supported on a waterlogged particleboard floor strip above a steel beam. Structural deterioration of the board and corroding bottom plates allow the entire building structure to sway under hand force.
A 3-metre-wide wardrobe wall opening was framed without a structural lintel, relying merely on trimming joists permitted only for spans up to 1.8 metres. An engineered lintel is required to carry upper wall loads.
The garage door frame is severely distorted beyond repair and covered in slapped mortar. In addition, electrical wiring penetrates steel structural members without insulating grommets or protective bushings.
Standards
- AS 1684.2 Said in videoSuggested reference, unverified
- AS/NZS 3000 Said in videoSuggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
ElectricalFinishes painting tilingWindows doors