Inspection Library

Waterproofing wet areas

Balcony Penetrations & Spigot Detailing

2 examples in 2 videos 2 major

What it is

Glass balustrade spigots were fixed over the top of the Scyon floor substrate instead of bolting into the structural subframe as specified by the manufacturer. Waterproofing terminations at the spigots have already developed bridge cracking.

Tiled external balcony lacks movement control joints and has glass balustrade spigots penetrating through the tiles and substrate. These mechanical penetrations puncture the waterproofing membrane without adequate sealing, and weep holes intended for subtile drainage have been blocked with silicone.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Finishes painting tilingStairs balustrades decks

Video examples