Blocked, sealed perimeter, or obstructed puddle flange drainage
What it is
Drain weep holes around the leak-control puddle flange are blocked with mortar and tile adhesive, trapping subsurface water beneath tiles.
The waste puddle flange has been completely sealed around its perimeter beneath the tiles, blocking subsurface drainage paths. Water penetrating through tile grout cannot enter the drain, causing moisture entrapment that breaks down adhesive and membrane systems.
Sub-tile drainage weepholes on the puddle flange have been fully sealed, trapping water beneath the floor tiles and screed. Trapped hydrostatic pressure causes extensive efflorescence and calcification leaching through the tile grout.
Standards
- AS 3740 Suggested reference, unverified
- Guide to Standards and Tolerances Said in video
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Finishes painting tilingPlumbing
Video examples
- I inspected a $20 Million Government Housing Build 9:38 majorBlocked puddle flange weep holes beneath tiles
- I inspected a $500K Dangerous Extension 14:08 majorShower waste puddle flange sealed perimeter preventing subsurface drainage
- Buying a Home in Australia? Watch This First to Avoid Costly Mistakes! 34:23 majorSealed puddle flange causing efflorescence and calcification
- Unveiling WA’s Homes: Are These Australia’s Best Builds? 12:01 minorSand and construction debris in shower waste puddle flange