Defective vertical membrane termination heights and upstands
What it is
The vertical upturn of the external waterproof membrane falls well short of the mandatory termination height above the finished tile level. The open threshold junction lacks proper flashing protection against wind-driven rain.
The vertical upturn of the balcony waterproofing membrane lacks essential mechanical protection, such as an overflashing or pressure flashing. Without protection, the exposed edge allows water bypass behind the membrane.
Balcony perimeter edges display inadequate vertical waterproofing membrane terminations measuring only 20 mm. Structural timber cut ends were left raw, unsealed, and directly exposed to ambient weathering.
Standards
- AS 1684 Suggested reference, unverified
- AS 4654 Said in video
- AS 4654.2 Said in videoSuggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Cladding render brickworkStairs balustrades decks
Video examples
- Unveiling Worst Builder of 2023 59:32 majorDefective vertical membrane termination height on balcony upstand
- I Inspected Troy Candy's Multi-Million Dollar Home: Shocking Finds! 15:50 majorUnprotected vertical membrane termination on balcony
- This Is What a Homeowner Got After Paying Hundreds of Thousands 21:36 majorInadequate membrane termination and unsealed cut timber on balcony
- I Inspected Australia's Best House… 8 Years Later 12:31 majorNon-compliant vertical upward membrane upturn on balcony
- I inspected a $20 Million Government Housing Build 27:38 majorDebonded membrane vertical termination without termination bar
- I Uncovered a $1.1M NSW Building Catastrophe 15:26 majorUnwaterproofed parapet wall and missing membrane upstands