Embedded door jambs and frames at wet areas
What it is
The bathroom door does not close freely and the jamb is embedded directly into floor tiling without waterproof membrane termination. The waterproofing failed to return into the door reveal, and tile adhesive bridges unsealed across the water-stop angle.
Timber door jambs in the wet area were installed embedded directly into floor tiles with no moisture isolation. Meter testing showed timber moisture levels elevated up to 32% due to water wicking into the frame.
The bathroom door frame jamb is embedded directly into floor bedding and tiles without any membrane application. Leaving timber doorposts unsealed allows moisture to rot the framing.
Standards
- AS 3740 Said in videoSuggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Finishes painting tilingWindows doors
Video examples
- Shocking Handover: The Home Inspection Nightmare That Will Leave You Stunned! 32:35 majorDoor frame embedded in screed without waterproofing membrane return
- "DREAM HOME" TO DISASTER: Why the QBCC is Failing Australia’s Homeowners 1:03:01 majorDoor jamb embedded in bathroom floor tiles causing moisture wicking
- I Inspected a Billionaire’s Mansion 8:25 majorDoor frame embedded in wet area floor tiles without waterproofing
- I Inspected Australia's Best House… 8 Years Later 15:58 majorEnsuite timber door frame embedded and absorbing trapped sub-tile moisture
- This Is How Families Lose Everything When Building A Home 4:56 majorDoor jambs embedded into wet area screed and unwaterproofed
- The Ghost Builder & the Haunted Home: Unmasking Construction Nightmares 17:16 majorTimber door jamb embedded beneath bathroom floor tiles without waterproofing
- Defect of the day! No waterproofing to the bathroom 0:26 majorSubstrate unprepared and door jambs not waterproofed below tiles
- Builder Challenges Inspection Results #siteinspections #tiktokinspector #inspection 2:20 majorDoor jambs and architraves embedded in tiles without waterproofing
- VMIA Insurance Inconsistencies: A Deep Dive into a Shangri-La Construction Inspection Report 24:41 minorDoor frames and architraves embedded into floor tiles