Insufficient falls and drainage ponding
What it is
The balcony floor lacks the mandatory minimum fall of 1:100 (10 mm per metre) toward the drainage outlet, resulting in stagnant water pooling. Screws penetrating the uncapped parapet also permit water penetration directly into lower framing.
Spirit level checks show the external terrace concrete slab is flat with insufficient fall towards drainage. Water ponds directly against the building, threatening ingress into the concrete slab.
Balcony subflooring sheets were installed in an un-staggered grid pattern without mandatory movement control joints. The external balcony substrate has no incorporated drainage fall, allowing rainwater to pond heavily over the structural frame.
Standards
- AS 3958.1 Suggested reference, unverified
- AS 4654 Said in video
- AS 4654.2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.