What it is

The balcony lacks a dedicated overflow device, having only a basic floor drain. Stormwater is currently discharging haphazardly onto the walkway below.

The enclosed balcony surface exhibits zero fall in sections, preventing proper water runoff. Additionally, the mandatory overflow opening is omitted, presenting a severe risk of internal flooding.

A broken floor tile was left unreplaced, and a drilled balcony overflow penetration lacks the necessary waterproof membrane return into the pipe sleeve.