Missing or defective balcony overflows and penetrations
What it is
The balcony lacks a dedicated overflow device, having only a basic floor drain. Stormwater is currently discharging haphazardly onto the walkway below.
The enclosed balcony surface exhibits zero fall in sections, preventing proper water runoff. Additionally, the mandatory overflow opening is omitted, presenting a severe risk of internal flooding.
A broken floor tile was left unreplaced, and a drilled balcony overflow penetration lacks the necessary waterproof membrane return into the pipe sleeve.
Standards
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Drainage stormwaterFinishes painting tilingStairs balustrades decks
Video examples
- Post Inspection | The Certifier Suspended & Builder Being Investigated Inspection Video… 2:49 majorMissing balcony overflow provision
- Post Inspection | The Certifier Suspended & Builder Being Investigated Inspection Video… 6:54 majorLack of required balcony falls and missing overflow
- $1M Home Disaster! This Builder’s Mistakes Will SHOCK You! 13:53 majorImproperly waterproofed balcony overflow penetrations and broken tiles
- $1M Home Disaster! This Builder’s Mistakes Will SHOCK You! 17:44 majorMissing balcony overflow and unprotected membrane around pipe penetrations