Inspection Library

Waterproofing wet areas

Missing or Defective Bathroom and Doorway Waterstops

7 examples in 5 videos 7 major

What it is

An open gap exists between the door trim and perimeter flashing at the bathroom entrance. Moisture migrating under the tile screed will bypass the threshold and rot adjacent subflooring.

Carpet was lifted at the upstairs bathroom entrance to reveal an open gap and no doorway water stop angle. Tiles must be removed to install required waterproofing containment.

During a flood test of the newly rectified bathroom, the waterstop was found to be non-compliant. The installation fails to prevent water escape as required.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Finishes painting tilingPlumbing

Video examples