Missing or non-compliant shower screen waterstop angles / vertical barriers
What it is
There is no vertical membrane upturn or separation barrier between the shower recess and the adjacent dry floor. Moisture penetrating beneath the tiled surface can migrate across the subfloor and rot underlying timber framing members.
The upstairs unenclosed walk-in shower lacks a vertical membrane upstand below the screen line, and the bathroom entrance doorway lacks a water stop angle. Without positive barriers, subterranean tile moisture will travel out of the wet area into dry zones.
A destructive probe under the aluminium floor angle confirms there is no vertical water stop terminating 5 mm above the finished tile level. As a result, subsurface tile water is uncontained and will migrate unimpeded across the subfloor to the doorway.
Standards
- AS 3740 Said in videoSuggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Finishes painting tilingWindows doors
Video examples
- The Ghost Builder & the Haunted Home: Unmasking Construction Nightmares 14:13 majorMissing vertical waterproofing separation between shower and wet area
- The Ghost Builder & the Haunted Home: Unmasking Construction Nightmares 16:03 majorOmission of shower screen membrane termination and doorway water stop
- The Ghost Builder & the Haunted Home: Unmasking Construction Nightmares 18:41 majorMissing vertical water stop barrier beneath upstairs walk-in shower screen
- She Paid $20,000 For This Balcony. The Next Was $18,000 Cash 7:21 majorMissing vertical separation in walk-in shower
- Cranbourne West Exposé: Revisiting the Construction Catastrophe 7:36 majorMissing waterstop angle beneath enclosed shower screen
- Cranbourne West Exposé: Revisiting the Construction Catastrophe 21:17 majorMissing waterstop angle beneath second home shower screen
- Unveiling WA’s Homes: Are These Australia’s Best Builds? 15:34 minorMissing shower screen water barrier
- The Shocking Truth: Builder Vanishes, Leaving Half-Finished Project... 28:12 majorMissing vertical waterstop separation between shower and wet area