Inspection Library

Waterproofing wet areas

Missing or non-compliant shower screen waterstop angles / vertical barriers

8 examples in 5 videos 7 major 1 minor

What it is

There is no vertical membrane upturn or separation barrier between the shower recess and the adjacent dry floor. Moisture penetrating beneath the tiled surface can migrate across the subfloor and rot underlying timber framing members.

The upstairs unenclosed walk-in shower lacks a vertical membrane upstand below the screen line, and the bathroom entrance doorway lacks a water stop angle. Without positive barriers, subterranean tile moisture will travel out of the wet area into dry zones.

A destructive probe under the aluminium floor angle confirms there is no vertical water stop terminating 5 mm above the finished tile level. As a result, subsurface tile water is uncontained and will migrate unimpeded across the subfloor to the doorway.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Finishes painting tilingWindows doors

Video examples