Planter box waterproofing, falls, and drainage defects
What it is
The base of the planter box is dead level with zero fall towards the drainage outlet, resulting in permanent water ponding across the waterproof membrane.
The planter drainage pipe was roughly trimmed without fitting a puddle flange or waterproofing bandage, creating a vulnerable leakage path at the penetration.
The enclosed planter box has no overflow outlet, ensuring that any blockage of the primary drain will cause catastrophic water flooding and containment failure.
Standards
- AS 4654.2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- I Uncovered a $1.1M NSW Building Catastrophe 17:12 majorFlat substrate and water ponding in planter box
- I Uncovered a $1.1M NSW Building Catastrophe 19:19 majorMissing puddle flange and bandage at planter drain penetration
- I Uncovered a $1.1M NSW Building Catastrophe 19:40 majorMissing secondary overflow in enclosed planter box