Shower Hob & Shower Waterstop Non-Compliance
What it is
An unenclosed shower lacks the mandatory floor waterstop positioned 1.5 m from the shower rose, and contains no floor membrane beneath the tiles. Without proper containment, water can freely migrate under tiles into adjacent habitable areas.
The waterstop angle on the raised shower hob finishes flush with the tiles instead of extending the required height above them. This configuration allows water to escape the shower enclosure and requires full demolition of the hob to rectify.
The waterstop angle in the second bathroom shower hob fails to terminate with the mandatory 15 mm height above the finished tiles. The shower requires demolition and reconstruction to meet waterproofing standards.